Review



diffusion tensor imaging diffusion weighted imaging tractography  (Bruker Corporation)


Bioz Verified Symbol Bruker Corporation is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 97

    Structured Review

    Bruker Corporation diffusion tensor imaging diffusion weighted imaging tractography
    Diffusion Tensor Imaging Diffusion Weighted Imaging Tractography, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 3085 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+tractography/Diffusion/pm22200882-66-0-19
    Average 97 stars, based on 3085 article reviews
    diffusion tensor imaging diffusion weighted imaging tractography - by Bioz Stars, 2026-10
    97/100 stars

    Images

    Related Articles

    Diffusion-based Assay:

    Article Title: Assessment of extremely premature lambs supported by the Extrauterine Environment for Neonatal Development (EXTEND).
    Article Snippet: .. T1, T2, and T2* weighted sequences and diffusion tensor imaging (DTI) were obtained on a Bruker Neo Biospec 7 T machine (Bruker, Billerica, MA). .. Post-hoc MRI image analysis (Invicro, LLC, Boston, MA) was performed by a boardcertified veterinary radiologist who was blinded to animal group.

    Article Title: Ultrahigh-resolution 7-Tesla anatomic magnetic resonance imaging and diffusion tensor imaging of ex vivo formalin-fixed human brainstem-cerebellum complex
    Article Snippet: .. Diffusion tensor imaging (DTI) lasted 48 h and 48 min, and subsequent anatomical imaging was performed using a 7-Tesla (7T) MRI system (Bruker Biospec 70/30 with 30-cm bore size) equipped with a 70-mm volume coil. ..

    Article Title: Clemastine enhances exercise-induced motor improvement in hypoxic ischemic rats.
    Article Snippet: Post-fixed whole-brain tissues (n = 6 per group; data of one trained HI rat were excluded owing to brain lesion failure) were placed in 0.2 mM gadolinium (Magnevist, Bayer Yakuhin, Osaka, Japan) containing PBS solution for 1–2 weeks. .. Diffusion tensor imaging (DTI) was performed using a 7-T Biospec 70/16 MRI scanner (Bruker BioSpin, Ettlingen, Germany) equipped with an actively shielded gradient coil at a maximum strength of 700 mT/m and a transmitting/receiving volume coil with an inner diameter of 38 mm (Bruker BioSpin). ..

    Article Title: Leukemia Inhibitory Factor as a late-stage treatment for delayed white matter loss in concussive head injury
    Article Snippet: Then, the brains were placed into a custom-built MRI-compatible tube filled with Fluorinert, an MRI susceptibility-matching fluid (Sigma-Aldrich, Inc., St. Louis, MO). .. Microstructural integrity was assessed using ex-vivo diffusion tensor imaging (DTI) of the brain samples using a horizontal bore 9.4T scanner (Bruker BioSpin, Billerica, MA). .. Each brain sample was glued to a plastic slide and placed in a 10ml plastic syringe filled with Fluorinert FC-43 (3MTM) (Sigma-Aldrich, St. Louis, MO, USA), a susceptibility-matched fluorocarbon-based fluid that generates no MRI signal.

    Article Title: Macroscopic brain region and network changes in a central-arterial-stiffness rat model.
    Article Snippet: Following immersion in 4% paraformaldehyde for 1 week, whole-brain tissues were placed in a 0.2-mM gadolinium (Magnevist, Bayer Yakuhin, Osaka, Japan) containing phosphate-buffered saline for 1–2 weeks. .. Ex vivo diffusion tensor imaging (DTI) was performed using a 7.0 T MRI system (Biospec; 70/16 Bruker BioSpin, Ettlingen, Germany) equipped with actively shielded gradients at a maximum strength of 700 mT/m using a 23-mm volume coil (Bruker Biospin, Ettlingen, Germany). ..

    Article Title: NAD + -boosting agent nicotinamide mononucleotide potently improves mitochondria stress response in Alzheimer’s disease via ATF4-dependent mitochondrial UPR
    Article Snippet: Incubate at 37 °C for 30 min. After being washed with pre-warmed PBS three times, it was stained with DRAQ5 (Thermo Scientific, catalog no.62254) and immediately observed under a microscope. .. High-resolution T2-weighted images and diffusion tensor imaging (DTI) were obtained using a 9.4 T BioSpec 117/16 USR scanner (Bruker BioSpin, Germany), operated with ParaVision® 6.0 (Bruker BioSpin), using orthogonal 1H volume coils (for mouse head imaging, ≥23 mm inner diameter) [ ]. ..

    Imaging:

    Article Title: Assessment of extremely premature lambs supported by the Extrauterine Environment for Neonatal Development (EXTEND).
    Article Snippet: .. T1, T2, and T2* weighted sequences and diffusion tensor imaging (DTI) were obtained on a Bruker Neo Biospec 7 T machine (Bruker, Billerica, MA). .. Post-hoc MRI image analysis (Invicro, LLC, Boston, MA) was performed by a boardcertified veterinary radiologist who was blinded to animal group.

    Article Title: Ultrahigh-resolution 7-Tesla anatomic magnetic resonance imaging and diffusion tensor imaging of ex vivo formalin-fixed human brainstem-cerebellum complex
    Article Snippet: .. Diffusion tensor imaging (DTI) lasted 48 h and 48 min, and subsequent anatomical imaging was performed using a 7-Tesla (7T) MRI system (Bruker Biospec 70/30 with 30-cm bore size) equipped with a 70-mm volume coil. ..

    Article Title: Clemastine enhances exercise-induced motor improvement in hypoxic ischemic rats.
    Article Snippet: Post-fixed whole-brain tissues (n = 6 per group; data of one trained HI rat were excluded owing to brain lesion failure) were placed in 0.2 mM gadolinium (Magnevist, Bayer Yakuhin, Osaka, Japan) containing PBS solution for 1–2 weeks. .. Diffusion tensor imaging (DTI) was performed using a 7-T Biospec 70/16 MRI scanner (Bruker BioSpin, Ettlingen, Germany) equipped with an actively shielded gradient coil at a maximum strength of 700 mT/m and a transmitting/receiving volume coil with an inner diameter of 38 mm (Bruker BioSpin). ..

    Article Title: Leukemia Inhibitory Factor as a late-stage treatment for delayed white matter loss in concussive head injury
    Article Snippet: Then, the brains were placed into a custom-built MRI-compatible tube filled with Fluorinert, an MRI susceptibility-matching fluid (Sigma-Aldrich, Inc., St. Louis, MO). .. Microstructural integrity was assessed using ex-vivo diffusion tensor imaging (DTI) of the brain samples using a horizontal bore 9.4T scanner (Bruker BioSpin, Billerica, MA). .. Each brain sample was glued to a plastic slide and placed in a 10ml plastic syringe filled with Fluorinert FC-43 (3MTM) (Sigma-Aldrich, St. Louis, MO, USA), a susceptibility-matched fluorocarbon-based fluid that generates no MRI signal.

    Article Title: Macroscopic brain region and network changes in a central-arterial-stiffness rat model.
    Article Snippet: Following immersion in 4% paraformaldehyde for 1 week, whole-brain tissues were placed in a 0.2-mM gadolinium (Magnevist, Bayer Yakuhin, Osaka, Japan) containing phosphate-buffered saline for 1–2 weeks. .. Ex vivo diffusion tensor imaging (DTI) was performed using a 7.0 T MRI system (Biospec; 70/16 Bruker BioSpin, Ettlingen, Germany) equipped with actively shielded gradients at a maximum strength of 700 mT/m using a 23-mm volume coil (Bruker Biospin, Ettlingen, Germany). ..

    Article Title: NAD + -boosting agent nicotinamide mononucleotide potently improves mitochondria stress response in Alzheimer’s disease via ATF4-dependent mitochondrial UPR
    Article Snippet: Incubate at 37 °C for 30 min. After being washed with pre-warmed PBS three times, it was stained with DRAQ5 (Thermo Scientific, catalog no.62254) and immediately observed under a microscope. .. High-resolution T2-weighted images and diffusion tensor imaging (DTI) were obtained using a 9.4 T BioSpec 117/16 USR scanner (Bruker BioSpin, Germany), operated with ParaVision® 6.0 (Bruker BioSpin), using orthogonal 1H volume coils (for mouse head imaging, ≥23 mm inner diameter) [ ]. ..

    Magnetic Resonance Imaging:

    Article Title: Ultrahigh-resolution 7-Tesla anatomic magnetic resonance imaging and diffusion tensor imaging of ex vivo formalin-fixed human brainstem-cerebellum complex
    Article Snippet: .. Diffusion tensor imaging (DTI) lasted 48 h and 48 min, and subsequent anatomical imaging was performed using a 7-Tesla (7T) MRI system (Bruker Biospec 70/30 with 30-cm bore size) equipped with a 70-mm volume coil. ..

    Article Title: Automated quality control of small animal MR neuroimaging data
    Article Snippet: Gradient: BGA 12S., 680 mT/m, Tx/RX .1H mouse quadrature volume coil (38mm ID) T2w T2_TRARE Bruker raw 10 13 Rivera- Olvera 117_m_Ri Mouse brain Bruker Biospec USR 117/16, BGA9S (600 mT/m and slew rates up to 6000 T/m/s) ; TX/RX: 1H quadrature cryogenic surface coil. .. T2w, DTI, rsfMRI DTIEPI, FLASH, EPI Bruker raw 20 14 Sta Maria 7_m_St Mouse brain 7T PET-MR system (MR Solutions Ltd, Guildford, UK), bore size: ~ 24 cm, gradient strength: 600 mT/m, coil: 20 mm inner diameter, 18 mm length, quadrature birdcage T2w, DTI FSE, FLASH, SE-EPI Nifti 17 15 Selim 7_m_Se Mouse/rat brain Bruker Biospec 70/30, Bruker 300 1H 2x2 mouse brain surface array or 300 1H 2x2 rat brain surface array T2w/T1w/DTI TurboRARE , WEIGHTED _SHORT, SDS Bruker raw 20/30 16 Selim 7_r_Se Mouse/rat brain Bruker Biospec 70/30, Bruker 300 1H 2x2 mouse brain surface array or 300 1H 2x2 rat brain surface array T2w/T1w/DTI TurboRARE , LTS, T2_WEIGH TED_SHO RT Bruker raw 20/30 17 Soria 7_r_So Rat brain 7T Bruker Biospec 70/30 horizontal animal scanner (400 mT/m, 12 cm inner diameter), 1H 2x2 rat brain surface array T2w, rs-fMRI 7T T2w (RARE),rsfMRI Nifti 8 (multiple time points) 18 Van Leeuwen 94_m_Va In vivo mouse brain 9.4 T Varian/Agilent, quadrature birdcage with ID 35 mm, 115_60_HD gradient (1000 mT/m) T2w, DTI TurboRARE Nifti 131 19 Vrooman 117_m_Vr In vivo mouse brain Bruker Biospec USR 117/16, BGA9S (600 mT/m and slew rates up to 6000 T/m/s) ; Mouse with single loop 10 mm diameter Rx surface coil and 089/072 mm Tx volume resonator. .. T2w, GE-EPI TurboRARE /rs-fMRI Nifti 12 (multiple time points) 20 Wenk 94_m_We In vivo mouse/rat/g erbil brain 9.4 Bruker Biospec USR 94/20, BGA12SHP (660 mT/m and slew rates up to 4570 T/m/s) ; Mouse with Array coil + 112/086 volume resonator; Gerbil with single-loop coil ID15 + 112/086 volume resonator; Rat with 075/40 volume resonator T2w, rs-fMRI, fMRI, DTI T2_ANATO MY, DTI_EPI_IS O, T2STAR, AUDISTIM Bruker raw 46/32/25 21 Wenk/Gonca lves 94_r_We In vivo mouse/rat/g erbil brain 9.4 Bruker Biospec USR 94/20, BGA12SHP (660 mT/m and slew rates up to 4570 T/m/s) ; Mouse with Array coil + 112/086 volume resonator; Gerbil with single-loop coil ID15 + 112/086 volume resonator; Rat with 075/40 volume resonator T2w, rs-fMRI, fMRI, DTI T2_ANATO MY, DTI_EPI_IS O, RSFMRI_E XPERIMEN T Bruker raw 46/32/25 22 Wenk/Michal ek 94_g_We In vivo mouse/rat/g erbil brain 9.4 Bruker Biospec USR 94/20, BGA12SHP (660 mT/m and slew rates up to 4570 T/m/s) ; Mouse with Array coil + 112/086 volume resonator; Gerbil with single-loop coil ID15 + 112/086 volume resonator; Rat with 075/40 volume resonator T2w, rs-fMRI, fMRI, DTI T2_TURBO RARE, NON_ROT ATING_EPI Bruker raw 46/32/25 23 Longo 7_m_Lo In vivo mouse abdominal 7T MicroImaging Bruker Avance III, 1H 30mm TX/RX body volume coil T2w, DTI T2 mic_rare, DtiEpi Bruker raw 20 1ex vivo.

    Article Title: Clemastine enhances exercise-induced motor improvement in hypoxic ischemic rats.
    Article Snippet: Post-fixed whole-brain tissues (n = 6 per group; data of one trained HI rat were excluded owing to brain lesion failure) were placed in 0.2 mM gadolinium (Magnevist, Bayer Yakuhin, Osaka, Japan) containing PBS solution for 1–2 weeks. .. Diffusion tensor imaging (DTI) was performed using a 7-T Biospec 70/16 MRI scanner (Bruker BioSpin, Ettlingen, Germany) equipped with an actively shielded gradient coil at a maximum strength of 700 mT/m and a transmitting/receiving volume coil with an inner diameter of 38 mm (Bruker BioSpin). ..

    Article Title: Macroscopic brain region and network changes in a central-arterial-stiffness rat model.
    Article Snippet: Following immersion in 4% paraformaldehyde for 1 week, whole-brain tissues were placed in a 0.2-mM gadolinium (Magnevist, Bayer Yakuhin, Osaka, Japan) containing phosphate-buffered saline for 1–2 weeks. .. Ex vivo diffusion tensor imaging (DTI) was performed using a 7.0 T MRI system (Biospec; 70/16 Bruker BioSpin, Ettlingen, Germany) equipped with actively shielded gradients at a maximum strength of 700 mT/m using a 23-mm volume coil (Bruker Biospin, Ettlingen, Germany). ..

    Positron Emission Tomography-Magnetic Resonance Imaging:

    Article Title: Automated quality control of small animal MR neuroimaging data
    Article Snippet: Gradient: BGA 12S., 680 mT/m, Tx/RX .1H mouse quadrature volume coil (38mm ID) T2w T2_TRARE Bruker raw 10 13 Rivera- Olvera 117_m_Ri Mouse brain Bruker Biospec USR 117/16, BGA9S (600 mT/m and slew rates up to 6000 T/m/s) ; TX/RX: 1H quadrature cryogenic surface coil. .. T2w, DTI, rsfMRI DTIEPI, FLASH, EPI Bruker raw 20 14 Sta Maria 7_m_St Mouse brain 7T PET-MR system (MR Solutions Ltd, Guildford, UK), bore size: ~ 24 cm, gradient strength: 600 mT/m, coil: 20 mm inner diameter, 18 mm length, quadrature birdcage T2w, DTI FSE, FLASH, SE-EPI Nifti 17 15 Selim 7_m_Se Mouse/rat brain Bruker Biospec 70/30, Bruker 300 1H 2x2 mouse brain surface array or 300 1H 2x2 rat brain surface array T2w/T1w/DTI TurboRARE , WEIGHTED _SHORT, SDS Bruker raw 20/30 16 Selim 7_r_Se Mouse/rat brain Bruker Biospec 70/30, Bruker 300 1H 2x2 mouse brain surface array or 300 1H 2x2 rat brain surface array T2w/T1w/DTI TurboRARE , LTS, T2_WEIGH TED_SHO RT Bruker raw 20/30 17 Soria 7_r_So Rat brain 7T Bruker Biospec 70/30 horizontal animal scanner (400 mT/m, 12 cm inner diameter), 1H 2x2 rat brain surface array T2w, rs-fMRI 7T T2w (RARE),rsfMRI Nifti 8 (multiple time points) 18 Van Leeuwen 94_m_Va In vivo mouse brain 9.4 T Varian/Agilent, quadrature birdcage with ID 35 mm, 115_60_HD gradient (1000 mT/m) T2w, DTI TurboRARE Nifti 131 19 Vrooman 117_m_Vr In vivo mouse brain Bruker Biospec USR 117/16, BGA9S (600 mT/m and slew rates up to 6000 T/m/s) ; Mouse with single loop 10 mm diameter Rx surface coil and 089/072 mm Tx volume resonator. .. T2w, GE-EPI TurboRARE /rs-fMRI Nifti 12 (multiple time points) 20 Wenk 94_m_We In vivo mouse/rat/g erbil brain 9.4 Bruker Biospec USR 94/20, BGA12SHP (660 mT/m and slew rates up to 4570 T/m/s) ; Mouse with Array coil + 112/086 volume resonator; Gerbil with single-loop coil ID15 + 112/086 volume resonator; Rat with 075/40 volume resonator T2w, rs-fMRI, fMRI, DTI T2_ANATO MY, DTI_EPI_IS O, T2STAR, AUDISTIM Bruker raw 46/32/25 21 Wenk/Gonca lves 94_r_We In vivo mouse/rat/g erbil brain 9.4 Bruker Biospec USR 94/20, BGA12SHP (660 mT/m and slew rates up to 4570 T/m/s) ; Mouse with Array coil + 112/086 volume resonator; Gerbil with single-loop coil ID15 + 112/086 volume resonator; Rat with 075/40 volume resonator T2w, rs-fMRI, fMRI, DTI T2_ANATO MY, DTI_EPI_IS O, RSFMRI_E XPERIMEN T Bruker raw 46/32/25 22 Wenk/Michal ek 94_g_We In vivo mouse/rat/g erbil brain 9.4 Bruker Biospec USR 94/20, BGA12SHP (660 mT/m and slew rates up to 4570 T/m/s) ; Mouse with Array coil + 112/086 volume resonator; Gerbil with single-loop coil ID15 + 112/086 volume resonator; Rat with 075/40 volume resonator T2w, rs-fMRI, fMRI, DTI T2_TURBO RARE, NON_ROT ATING_EPI Bruker raw 46/32/25 23 Longo 7_m_Lo In vivo mouse abdominal 7T MicroImaging Bruker Avance III, 1H 30mm TX/RX body volume coil T2w, DTI T2 mic_rare, DtiEpi Bruker raw 20 1ex vivo.

    In Vivo:

    Article Title: Automated quality control of small animal MR neuroimaging data
    Article Snippet: Gradient: BGA 12S., 680 mT/m, Tx/RX .1H mouse quadrature volume coil (38mm ID) T2w T2_TRARE Bruker raw 10 13 Rivera- Olvera 117_m_Ri Mouse brain Bruker Biospec USR 117/16, BGA9S (600 mT/m and slew rates up to 6000 T/m/s) ; TX/RX: 1H quadrature cryogenic surface coil. .. T2w, DTI, rsfMRI DTIEPI, FLASH, EPI Bruker raw 20 14 Sta Maria 7_m_St Mouse brain 7T PET-MR system (MR Solutions Ltd, Guildford, UK), bore size: ~ 24 cm, gradient strength: 600 mT/m, coil: 20 mm inner diameter, 18 mm length, quadrature birdcage T2w, DTI FSE, FLASH, SE-EPI Nifti 17 15 Selim 7_m_Se Mouse/rat brain Bruker Biospec 70/30, Bruker 300 1H 2x2 mouse brain surface array or 300 1H 2x2 rat brain surface array T2w/T1w/DTI TurboRARE , WEIGHTED _SHORT, SDS Bruker raw 20/30 16 Selim 7_r_Se Mouse/rat brain Bruker Biospec 70/30, Bruker 300 1H 2x2 mouse brain surface array or 300 1H 2x2 rat brain surface array T2w/T1w/DTI TurboRARE , LTS, T2_WEIGH TED_SHO RT Bruker raw 20/30 17 Soria 7_r_So Rat brain 7T Bruker Biospec 70/30 horizontal animal scanner (400 mT/m, 12 cm inner diameter), 1H 2x2 rat brain surface array T2w, rs-fMRI 7T T2w (RARE),rsfMRI Nifti 8 (multiple time points) 18 Van Leeuwen 94_m_Va In vivo mouse brain 9.4 T Varian/Agilent, quadrature birdcage with ID 35 mm, 115_60_HD gradient (1000 mT/m) T2w, DTI TurboRARE Nifti 131 19 Vrooman 117_m_Vr In vivo mouse brain Bruker Biospec USR 117/16, BGA9S (600 mT/m and slew rates up to 6000 T/m/s) ; Mouse with single loop 10 mm diameter Rx surface coil and 089/072 mm Tx volume resonator. .. T2w, GE-EPI TurboRARE /rs-fMRI Nifti 12 (multiple time points) 20 Wenk 94_m_We In vivo mouse/rat/g erbil brain 9.4 Bruker Biospec USR 94/20, BGA12SHP (660 mT/m and slew rates up to 4570 T/m/s) ; Mouse with Array coil + 112/086 volume resonator; Gerbil with single-loop coil ID15 + 112/086 volume resonator; Rat with 075/40 volume resonator T2w, rs-fMRI, fMRI, DTI T2_ANATO MY, DTI_EPI_IS O, T2STAR, AUDISTIM Bruker raw 46/32/25 21 Wenk/Gonca lves 94_r_We In vivo mouse/rat/g erbil brain 9.4 Bruker Biospec USR 94/20, BGA12SHP (660 mT/m and slew rates up to 4570 T/m/s) ; Mouse with Array coil + 112/086 volume resonator; Gerbil with single-loop coil ID15 + 112/086 volume resonator; Rat with 075/40 volume resonator T2w, rs-fMRI, fMRI, DTI T2_ANATO MY, DTI_EPI_IS O, RSFMRI_E XPERIMEN T Bruker raw 46/32/25 22 Wenk/Michal ek 94_g_We In vivo mouse/rat/g erbil brain 9.4 Bruker Biospec USR 94/20, BGA12SHP (660 mT/m and slew rates up to 4570 T/m/s) ; Mouse with Array coil + 112/086 volume resonator; Gerbil with single-loop coil ID15 + 112/086 volume resonator; Rat with 075/40 volume resonator T2w, rs-fMRI, fMRI, DTI T2_TURBO RARE, NON_ROT ATING_EPI Bruker raw 46/32/25 23 Longo 7_m_Lo In vivo mouse abdominal 7T MicroImaging Bruker Avance III, 1H 30mm TX/RX body volume coil T2w, DTI T2 mic_rare, DtiEpi Bruker raw 20 1ex vivo.

    other:


    Ex Vivo:

    Article Title: Macroscopic brain region and network changes in a central-arterial-stiffness rat model.
    Article Snippet: Following immersion in 4% paraformaldehyde for 1 week, whole-brain tissues were placed in a 0.2-mM gadolinium (Magnevist, Bayer Yakuhin, Osaka, Japan) containing phosphate-buffered saline for 1–2 weeks. .. Ex vivo diffusion tensor imaging (DTI) was performed using a 7.0 T MRI system (Biospec; 70/16 Bruker BioSpin, Ettlingen, Germany) equipped with actively shielded gradients at a maximum strength of 700 mT/m using a 23-mm volume coil (Bruker Biospin, Ettlingen, Germany). ..



    Similar Products

    90
    Brainlab AG diffusion tensor imaging tractography
    Diffusion Tensor Imaging Tractography, supplied by Brainlab AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+tractography/diffusion+tensor+imaging+tractography/pmc09025938-25-0-9
    Average 90 stars, based on 1 article reviews
    diffusion tensor imaging tractography - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Kamada diffusion tensor imaging-based tractography
    DVHs of IMRT plans. DVHs of IMRT plans of the case 1 (A) and case 2 (B) shown in Fig. 2. Solid and dotted lines represent the plans with dose constraints for the corticospinal tract (Fig. 2A and C) and those without dose constraints (Fig. 2B and D), respectively. DVH analyses revealed that the doses to the corticospinal tracts and the brainstem were diminished by integrating <t>tractography</t> into IMRT planning, while PTV dose coverages were comparable. Light green, orange, green, purple, pink, and light blue lines represent DVHs of PTV1, PTV2, right corticospinal tract (CST-R), left corticospinal tract (CST-L), brainstem, and optic tract, respectively.
    Diffusion Tensor Imaging Based Tractography, supplied by Kamada, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+tractography/tractography/pmc04150090-166-9-2
    Average 90 stars, based on 1 article reviews
    diffusion tensor imaging-based tractography - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    The Virtual Brain non-invasive tractography methods such as diffusion tensor or spectrum imaging
    DVHs of IMRT plans. DVHs of IMRT plans of the case 1 (A) and case 2 (B) shown in Fig. 2. Solid and dotted lines represent the plans with dose constraints for the corticospinal tract (Fig. 2A and C) and those without dose constraints (Fig. 2B and D), respectively. DVH analyses revealed that the doses to the corticospinal tracts and the brainstem were diminished by integrating <t>tractography</t> into IMRT planning, while PTV dose coverages were comparable. Light green, orange, green, purple, pink, and light blue lines represent DVHs of PTV1, PTV2, right corticospinal tract (CST-R), left corticospinal tract (CST-L), brainstem, and optic tract, respectively.
    Non Invasive Tractography Methods Such As Diffusion Tensor Or Spectrum Imaging, supplied by The Virtual Brain, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+tractography/non+invasive+tractography+methods+such+as+diffusion+tensor+or+spectrum+imaging/10__1186_slash_1471___2202___14___s1___p198-2-63-34
    Average 90 stars, based on 1 article reviews
    non-invasive tractography methods such as diffusion tensor or spectrum imaging - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    97
    Bruker Corporation diffusion tensor imaging diffusion weighted imaging tractography
    DVHs of IMRT plans. DVHs of IMRT plans of the case 1 (A) and case 2 (B) shown in Fig. 2. Solid and dotted lines represent the plans with dose constraints for the corticospinal tract (Fig. 2A and C) and those without dose constraints (Fig. 2B and D), respectively. DVH analyses revealed that the doses to the corticospinal tracts and the brainstem were diminished by integrating <t>tractography</t> into IMRT planning, while PTV dose coverages were comparable. Light green, orange, green, purple, pink, and light blue lines represent DVHs of PTV1, PTV2, right corticospinal tract (CST-R), left corticospinal tract (CST-L), brainstem, and optic tract, respectively.
    Diffusion Tensor Imaging Diffusion Weighted Imaging Tractography, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+tractography/Diffusion/pm22200882-66-0-19
    Average 97 stars, based on 1 article reviews
    diffusion tensor imaging diffusion weighted imaging tractography - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    90
    Kamada diffusion tensor imaging tractography
    DVHs of IMRT plans. DVHs of IMRT plans of the case 1 (A) and case 2 (B) shown in Fig. 2. Solid and dotted lines represent the plans with dose constraints for the corticospinal tract (Fig. 2A and C) and those without dose constraints (Fig. 2B and D), respectively. DVH analyses revealed that the doses to the corticospinal tracts and the brainstem were diminished by integrating <t>tractography</t> into IMRT planning, while PTV dose coverages were comparable. Light green, orange, green, purple, pink, and light blue lines represent DVHs of PTV1, PTV2, right corticospinal tract (CST-R), left corticospinal tract (CST-L), brainstem, and optic tract, respectively.
    Diffusion Tensor Imaging Tractography, supplied by Kamada, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+tractography/tractography/pm22847766-182-6-32
    Average 90 stars, based on 1 article reviews
    diffusion tensor imaging tractography - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    The Virtual Brain diffusion tensor imaging based tractography
    DVHs of IMRT plans. DVHs of IMRT plans of the case 1 (A) and case 2 (B) shown in Fig. 2. Solid and dotted lines represent the plans with dose constraints for the corticospinal tract (Fig. 2A and C) and those without dose constraints (Fig. 2B and D), respectively. DVH analyses revealed that the doses to the corticospinal tracts and the brainstem were diminished by integrating <t>tractography</t> into IMRT planning, while PTV dose coverages were comparable. Light green, orange, green, purple, pink, and light blue lines represent DVHs of PTV1, PTV2, right corticospinal tract (CST-R), left corticospinal tract (CST-L), brainstem, and optic tract, respectively.
    Diffusion Tensor Imaging Based Tractography, supplied by The Virtual Brain, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+tractography/diffusion+tensor+imaging+based+tractography/pmc03699761-135-46-4
    Average 90 stars, based on 1 article reviews
    diffusion tensor imaging based tractography - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    KU Leuven diffusion tensor imaging tractography
    DVHs of IMRT plans. DVHs of IMRT plans of the case 1 (A) and case 2 (B) shown in Fig. 2. Solid and dotted lines represent the plans with dose constraints for the corticospinal tract (Fig. 2A and C) and those without dose constraints (Fig. 2B and D), respectively. DVH analyses revealed that the doses to the corticospinal tracts and the brainstem were diminished by integrating <t>tractography</t> into IMRT planning, while PTV dose coverages were comparable. Light green, orange, green, purple, pink, and light blue lines represent DVHs of PTV1, PTV2, right corticospinal tract (CST-R), left corticospinal tract (CST-L), brainstem, and optic tract, respectively.
    Diffusion Tensor Imaging Tractography, supplied by KU Leuven, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+tractography/diffusion+tensor+imaging+tractography/pm22327793-2-73-87
    Average 90 stars, based on 1 article reviews
    diffusion tensor imaging tractography - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    DVHs of IMRT plans. DVHs of IMRT plans of the case 1 (A) and case 2 (B) shown in Fig. 2. Solid and dotted lines represent the plans with dose constraints for the corticospinal tract (Fig. 2A and C) and those without dose constraints (Fig. 2B and D), respectively. DVH analyses revealed that the doses to the corticospinal tracts and the brainstem were diminished by integrating tractography into IMRT planning, while PTV dose coverages were comparable. Light green, orange, green, purple, pink, and light blue lines represent DVHs of PTV1, PTV2, right corticospinal tract (CST-R), left corticospinal tract (CST-L), brainstem, and optic tract, respectively.

    Journal: Reports of Practical Oncology and Radiotherapy

    Article Title: Corticospinal tract-sparing intensity-modulated radiotherapy treatment planning

    doi: 10.1016/j.rpor.2014.01.002

    Figure Lengend Snippet: DVHs of IMRT plans. DVHs of IMRT plans of the case 1 (A) and case 2 (B) shown in Fig. 2. Solid and dotted lines represent the plans with dose constraints for the corticospinal tract (Fig. 2A and C) and those without dose constraints (Fig. 2B and D), respectively. DVH analyses revealed that the doses to the corticospinal tracts and the brainstem were diminished by integrating tractography into IMRT planning, while PTV dose coverages were comparable. Light green, orange, green, purple, pink, and light blue lines represent DVHs of PTV1, PTV2, right corticospinal tract (CST-R), left corticospinal tract (CST-L), brainstem, and optic tract, respectively.

    Article Snippet: 39–42 Notably, Kamada et al. confirmed the reliability of diffusion tensor imaging-based tractography by showing a strong correlation between the stimulus intensity of direct fiber stimulation during operation and the distance from the stimulus point to the corticospinal tract on tractography-integrated neuronavigation images.

    Techniques: